LightSystem® Fiber Optic Cable Multimode - International

LightSystem<sup>®</sup> Fiber Optic Cable Multimode - InternationalEnlarge this image
Product Resources
Part Number Part Numbers
PDF Specification Sheet

Overview

Siemon’s LightSystem 50 and 62.5 micron fiber cables are perfectly suited for the support of Gigabit Ethernet and Fast Ethernet applications at all horizontal work stations, riser, and short length backbone locations.

Compliance

  • ISO/IEC 11801:2002 (OM1)
  • TIA/EIA-568-B.3
  • TIA-598-C
  • LS0H: IEC 60332-1, IEC 61034, IEC 60754
  • Communications Type OFNR (UL) and CSA FT4 c(UL)
  • Communications Type OFNP (UL) and CSA FT6 c(UL)

Cable Construction

  • Tight buffer design for easy connectorization
  • Flexible, lightweight for ease of installation
  • Thermoplastic outer and inner (sub-unit) jackets
  • Aramid yarn strength members
  • Dielectric central strength member
  • Color coded per TIA-598-C

Part of the LightSystem (1 Gb/s) Fiber cabling system.


Part Numbers

9F5B(X)-12D(XXXX) (Picture) 50/125µm multimode, fiber count = 12, Construction = 1 tube of 12 fibers
9F5B(X)-16A(XXXX) (Picture) 50/125µm multimode, fiber count = 16, Construction = 4 tubes of 4 fibers
9F5B(X)-24B(XXXX) (Picture) 50/125µm multimode, fiber count = 24, Construction = 4 tubes of 6 fibers
9F5B(X)-2F(XXXX) (Picture) 50/125µm multimode, fiber count = 2, Construction = 1 tube of 2 fibers
9F5B(X)-48D(XXXX) (Picture) 50/125µm multimode, fiber count = 48, Construction = 4 tubes of 12 fibers
9F5B(X)-4A(XXXX) (Picture) 50/125µm multimode, fiber count = 4, Construction = 1 tube of 4 fibers
9F5B(X)-6B(XXXX) (Picture) 50/125µm multimode, fiber count = 6, Construction = 1 tube of 6 fibers
9F5B(X)-72D(XXXX) (Picture) 50/125µm multimode, fiber count = 72, Construction = 6 tubes of 12 fibers
9F5B(X)-8C(XXXX) (Picture) 50/125µm multimode, fiber count = 8, Construction = 1 tube of 8 fibers
9F6B(X)-12D(XXXX) (Picture) 62.5/125µm multimode, fiber count = 12, Construction = 1 tube of 12 fibers
9F6B(X)-16A(XXXX) (Picture) 62.5/125µm multimode, fiber count = 16, Construction = 4 tubes of 4 fibers
9F6B(X)-2F(XXXX) (Picture) 62.5/125µm multimode, fiber count = 2, Construction = 1 tube of 2 fibers
9F6B(X)-48D(XXXX) (Picture) 62.5/125µm multimode, fiber count = 48, Construction = 4 tubes of 12 fibers
9F6B(X)-4A(XXXX) (Picture) 62.5/125µm multimode, fiber count = 4, Construction = 1 tube of 4 fibers
9F6B(X)-6B(XXXX) (Picture) 62.5/125µm multimode, fiber count = 6, Construction = 1 tube of 6 fibers
9F6B(X)-72D(XXXX) (Picture) 62.5/125µm multimode, fiber count = 72, Construction = 6 tubes of 12 fibers
9F6B(X)-8C(XXXX) (Picture) 62.5/125µm multimode, fiber count = 8, Construction = 1 tube of 8 fibers

Use (X) to specify cable rating: 1 = OFNR, 2 = OFNP, 3 = LS0H
Use (XXXX) to specify length in kilometer, use four characters including decimal point.
The last "X" must be a zero (0) or five (5) only.
Example p/n: 9F5B1-12D1.50:
(1.5 kilometers [1500 meters] of 50/125µm 12-strand riser rated fiber optic cable)
For orders of less than 1 km, the first "X" must be zero (0).
Example: 9F5B1-12D0.55 (.550 kilometers [550 meters] of 50/125µm 12-strand riser rated fiber optic cable)

Because we continuously improve our products, Siemon reserves the right to change specifications and availability without prior notice

Data Center eBook

Data Center E-Book: Deploying, Managing and Securing an Efficient Physical Infrastructure

61-pages

» Download eBook

Shielded Learning Center
Follow Siemon


Find Siemon Partners

» Find Siemon Distributors

» Find Certified Installers & Consultants

Technology Leadership

Cisco Technology Developer Partner



Cisco Compatible


» Learn More



2010 System Catalog
Siemon 2010 System Catalog

Arranged by system to simplify the selection of Siemon end-to-end cabling systems.
»Order Now


Case Studies - See how Siemon is connecting the world to a higher standard